生物技术与植物化学杂志

抽象的

Euro Biotechnology 2018: Towards a better understanding of the biochemical response to stressors such as disease or toxins: IROA measurement system and workflow - Felice A de Jong - IIROA Technologies LLC, USA

Felice A de Jong

Statement of the Problem: Metabolites such as glucose respond to stressors that disrupt homeostasis, such as toxins. Humans produce 1000???s of metabolites and the measurement of these molecules provides a treasure-trove of information that can be used to elucidate the health status of an organism. The measurement of metabolites (metabolomics) is widely achieved using liquid chromatography-mass spectrometry (LC-MS) whereby molecules are charged or ionized, fragmented and separated to generate peaks for 100s of metabolites from a single sample, i.e. a drop of blood. Advances in mass spectrometry, including accurate mass and high resolution, have enabled the measurement of many metabolites but still, over 60% of the data generated remains a mystery. One bottleneck is piecing together fragments with their parent molecules to achieve accurate identification of as many metabolites as possible. Confounding the issue is that most unknown peaks arise from artefacts including contaminants. The purpose of this study is to describe a QC IROA metabolomics workflow that removes artefactual peaks and increases accurate metabolite identification. Methodology & Theoretical Orientation: Two sets of 100???s of stable-labeled internal standards were generated; one enriched in one isotope and depleted in its other isotopic form, and the other its mirror image (95% 13C6 and 5% 12C6 and 5% 13C6 and 95% 12C6) so that all of the molecules in each standard exhibited unique mass spectral patterns, all mathematically calculable and easily characterized by Clusterfinder software algorithms. The paired internal standards (mixed 1:1; ???Matrix???) was analyzed by LC-MS and ClusterFinder to generate an accurate library of compound and peak identifiers, including mass and retention time. The heavier isotopic standard (95% 13C6) was spiked into samples and analyzed by LC-MS. The Matrix was analyzed every ten samples to account for fluctuations in mass and retention time drift during the run. Cluster Finder located the labeled mass spectral peaks in the heavy standard and then located, identified and quantitated matching native (unlabeled) metabolite peaks in samples using the library. Peak correlation was performed to pair fragments and parent peaks. An example of this technology will be shown that illustrates the toxicological mechanism of action of flucytosine in yeast. Conclusion & Significance: Metabolite identification and quantitation are achieved using a reproducible QC workflow enabling accurate results which can be used to interrogate living system

免责声明: 此摘要通过人工智能工具翻译,尚未经过审核或验证。