抽象的
Mal-united Mandible fracture- a case report and literature review
Sandeep Kumar Jha, Debjit Dhamali, Debajyoti Roy, Sharmishtha Chakroborty
Mandible fracture is usually treated primarily with miniplates, lag screws or Kirschner’s wire with or without maxilla mandibular fixa-tion (MMF). The timing of surgical treatment is determined by multitude of factors includ-ing neurological and general condition of the patient. A delay in treatment at times may cause com-plications like non-union and malunion with occlusal abnormalities and disturbance in temporomandibular joint function. Here we are presenting a case of Mandible fracture that went into malunion due to delay in treat-ment. The malunited fracture was successful-ly repaired with a good occlusion.
免责声明: 此摘要通过人工智能工具翻译,尚未经过审核或验证。